CHAPTER 2. ADJUSTMENTS
[1] Adjustments
General
Since the following adjustments and settings are provided for this model,
make adjustments and/or setup as necessary.
1. Adjustments
Adjustments of output voltage (FACTORY ONLY)
1. Install the power supply unit in the machine.
2. Set the recording paper and document.
3. When the document is loaded, power is supplied to the output lines.
Confirm that outputs are within the limits below.
Output voltage settings
Fig. 1
Fig. 3
Printer PWB
1
CNPWCN101
12
1
12
Power
Supply
PWB
2. High voltage power adjustments
The high voltage power adjustments are composed of the MC output
voltage adjustment and the DC bias output voltage adjustment. Either
adjustment is performed with the diag function. (MAIN CHG ADJUST
MODE)
MC output voltage adjustment
In the measurement circuit shown below, adjust VR1 to be –1050V ~
–1200V (aim at –1100V)
MC
Measure with the high
voltage tester
(effective value meter).
DRUM
• Capacitor: 1000pF/3KV (VCKYQY3FB102K)
• Diode: SHV-03 (VHDSHV03///-1)
Fig.2
VR1 (MC output voltage adjustment volume)
+
–
MC output
voltage check
Output Voltage limits
+5V 4.75V~5.25V
+24VH 23.04V~24.96V
+24V* 23.04V~24.96V
PIN No.
Connector
No.
CNPW
1 +5V
2DG
3DG
4 +24VH
5MG
6MG
7 +24VS
8 PWRLY–
9 HLON–
10 +24V
11 +24V
12 ZC