Daewoo DR-C922B Specifiche Pagina 9

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 31
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 8
A. When initial power input or returning power failure.
if the temperature at the Defrost Sensor is below 3.5 C, Defrost Mode starts.
( It prceeds from 'PRE-COOL' ), [ PRE-COOL - Heater On - Pause (10min) - Normal Operation ]
B. Initial defrost mode starts after 'Prevention of Compressor Restart'. ( Refer to function No. 5 )
FUNCTIONS
Initial Defrost
Flow Chart of Defrost Start
Defrost Mode
CONTROL OBJECTINPUT
Total COMP Work Time / COMP Working Rate
Total Door Open Time / RT
3. Defrost Mode
Comp time >= 2 hours
Start
Yes
No
Total time >= 60 hours
Comp time >= 14
Comp time >= 6 hours
Comp Rate >= 90%
Any Error?
RT Temp >= 38C
Total door open time >=
2min?
END
Defrosting Start
Yes
Yes
Yes
Yes
Yes
Ye
Yes
No
No
No
No
No
No
No
8