Manual de servicioSplit Acondicionador de Aire Modelo: Aviso:En este manual,algunas partes pueden cambiar sin previo aviso en la lista de partes
9Connecting PipeBodyFrame GrilleGrille InsertPlate Mounting4307101080Filter-L Filter-RREMOCON◆DSA-245L, 245P200298MODESLEEPON/OFFTIMERENTER/ CANCE
10◆INSTALLING THE INSTALLATION PLATEUnit : mm• DSA-245L, 245P• DSA-185L, 185P• DSA-125L, 125P• DSA-095L
112OUTDOOR UNIT◆DSA-095LOutletFoot CushionCabinet FrontCabinet SidePanel TopGuide SupportSVC CoverServise ValveInletOutletInlet256286324539549460654
12◆DSA-125L, 125P, 185L, 185PInletOutletOutletFoot CushionCabinet FrontCabinet Side Panel Top Guide SupportSVC CoverServise Valve580800320360400589615
13◆DSA-245L, 245PInlet325350380673697OutletOutletFoot CushionCabinet FrontCabinet SidePanel TopGuide SupportSVC CoverServise ValveInlet549872
141NAME AND FUNCTION OF PARTSIndoor Unit3. OPERATION◆DSA-095LFan Direction(Up/Down)Connection CoverRemove cover to accessthe AC connection fromthis un
15Indoor Unit◆DSA-125L, 125PRemoves small dust and generates (-) ions.(DSA-125P)Electrostatic FilterRemoves dust particlesfrom the air(DSA-125L)Electr
16Indoor Unit◆ DSA-185L, 185PIndoor CoverDeodorizing FilterRemoves bad smellsfrom the air.Test/Emergency/ Remote SwitchSlide to selectthe desired posi
17Indoor CoverDeodorizing FilterRemoves badsmells from the air.Emergency/Remote SwitchIndicatorsIndicate theAC setting.RemoteSensorPower PlugLCD Remot
18Name of Each Button2 REMOTE CONTROLLERMODESLEEP PLASMAON/OFFTIMERENTER/ CANCELFAN SPEEDTURBO/MILDDisplayDisplays informationpertaining to unit.(
CONTENTS1. Specifications...22. Outline and Dim
19If you set time in OFF-Timer Mode, the unit will stop at the set time.If you set time in ON-Timer Mode, the unit will run at the set time.(1) Range
20Fan Speed (Indoor Unit)(1) Motor speed (high speed, normal speed, low speed).(2) Remote controller setting fan speed. (Auto, L, M, H, Natural)(3) Re
21(1) When the remote controller is lost, damaged or the battery is discharged, the Emergency operation can beused to run the unit.(2) The setting con
22Frost Prevention of Indoor UnitWhen the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coiltemperatur
231) Cooling Mode1Fan Speed: Super high speed2Air discharge direction: Fixed3Set temperature: 18°C (Fixed)4Compressor and Outdoor FanThe air discharge
24Self-Diagnostic FunctionThe control will contain diagnostic test to verify the integrity of the system.(1)Error Code Display Pattern1 ON LAMP: Blink
254. WIRING DIAGRAMIndoor Unit◆ DSA-095L ◆ DSA-125L◆ DSA-185L, 245L
26Indoor Unit◆ DSA-125P ◆ DSA-185P◆ DSA-245P
27Outdoor Unit◆ DSA-095L ◆ DSA-125L, 125P◆ DSA-185L, 185P ◆ DSA-245L, 245P
285. CONTROL BLOCK DIAGRAM◆DSA-095L, DSA-125L, 125P
2MODEL DSA-095LITEM Function CoolingClass T1Power AC 230V/ 60HzCapacity KJ/h 9,000Btu/h 8,531Dehumidification l/h 1.1Running Current A 3.6Power Input
◆DSA-185L, 185P29
◆DSA-245L, 245P30
31213I.D.CSRSWINGMOTORROOM AIRSENSORRemote ControllerTRANS-FORMERRL1COMP.RELAYTRIACOVERLOADPRO-TECTORCOMPRESSOROUTDOOR UNITFAN MOTORTERMINALBLOCKNLIND
32Description1. After the power ON/OFF button is pressed once, the relay and triac are turned ON or OFF per the remotecontrol setpoint.– TRIAC is cont
337. TROUBLE SHOOTINGOutdoor unit doesnot run?(note. 1)Doesthe compressor runnormally?Indoor unit doesnot run(note 1)Check the failurecode according t
34Note 1)1 Neither indoor unit nor outdoor unit runs.Check the following points first. (There are following case in normal operation)a. Is the timer m
35Confirm following statement.When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate.1 Check the function select sw
36Check rotation of indoor fan Rotate indoor fan by handCheck input Voltage of FanMotor connector at power P.C.BCheck the winding resistance of Indoor
37Confirm following statement.When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate.1 Is the setting temperature p
38- Check the following at cooling modeCheck the voltge between and of indoor unit terminalYLCheck the voltge between and of outdoor unit terminalYL
3MODEL DSA-125L, 125PITEM Function CoolingClass T1Power AC 230V/ 60HzCapacity KJ/h 12,500Btu/h 11,848Dehumidification l/h 1.35Running Current A 4.7Po
39◆DSA-095L, DSA-125L, 125P8. PCB DRIVING DESCRIPTION
40◆DSA-185L, 185P
41◆DSA-245L, 245P
◆DSA-095L PART LIST (Control PCB Assy)No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKBD1 DS1NB80--- DIODE BRIDGE S1NB80,800V 1 EABZ1 3105698200 BU
No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKPCB 3104398104 PCB CONTROL 162.5X140X1.6T 1 EAPT1 1TLP560J-- IC PHOTO COUPLER TLP 560J 1 EAR1 RD-4K
44◆DSA-125L, 125P PART LIST (Control PCB Assy)No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKBD1 DS1NB80--- DIODE BRIDGE S1NB80,800V 1 EABZ1 31056
45No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKPC2 1TLP421--- IC PHOTOCOUPLER TLP421 1 EAPCB 3104398113 PCB CONTROL 180X126X1.6T 1 EAPT1 1TLP560
46◆DSA-185L, 185P PART LIST (Control PCB Assy)No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKCA1 CN5XD104M- C-ARRAY 6P(F5)X 104Z 1 EACA2 CN3XD104M
47No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKR1 RD-4K103J- R CARBON FILM 1/4 10K OHM J 1 EAR10 RD-4K562J- R CARBON FILM 1/4 5.6K OHM J 1 EAR11
48No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKBZ1 3105698200 BUZZER DP-2520BA 1 EAC1 CLV-B3104M C-LINE ACROSS 275V 104K(PILKOR) 1 EAC2 CLV-B310
4MODEL DSA-185L, 185PITEM Function CoolingClass T1Power AC 230V/ 60HzCapacity KJ/h 17,500Btu/h 16,588Dehumidification l/h 2.0Running Current A 7.2Pow
49◆DSA-245L, 245P PART LIST (Control PCB Assy)No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKBZ1 3105698200 BUZZER DP-2520BA 1 EACA1 CN5XD104M- C-
50No. PART CODE PART NAME SPEC. Q'TY UNIT REMARKJ1 14 3109400100 JUMPER 10MM 14 EAJ1~14 3109400100 JUMPER 10MM 14 EAL1 52C1374001 COIL 130UF 3A 1
◆LED PCB ASS`Y (MODEL : DSA-095L)No PART CODE PART NAME SPEC Q'TY UNIT REMARKCC1 CDXE1H104M C-MULTI CR501B-Z5U,104Z,50V 1 EACN1 3108804800 WAFER
52Power Supply(1)DESCRIPTIONDC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac DrivingPhoto Triac, Buzzer
53Room temperature and Evaporator temperature Sensor InputDESCRIPTIONNumber 24, 25 of Micom is Terminal of A/D convertor Input.Room temperature and Ev
54Triac Driving(4)DESCRIPTIONNumber 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is suppliedTrigger Signal
55DESCRIPTIONSignal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gottenfid of Carrier (38KHz) from
56DESCRIPTIONMICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.Micom Power Supply(7)VDD 42CE510µ
57DESCRIPTIONVoltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detectPower ON and Voltage less than 4.25V
58DESCRIPTIONMicom 34 Terminal put out Buzzer Driving Pulse,its output is driving Buzzer through Buffer.Ocillatory Frequency of buzzer is selected byi
5MODEL DSA-245L, 245PITEM Function CoolingClass T1Power AC 230V/ 60HzCapacity KJ/h 23,500Btu/h 22,275Dehumidification l/h 2.7Running Current A 10.0Po
59DESCRIPTIONIt defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom. Detail Driving is as following Fig 11-1.R1
60DESCRIPTIONThere are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.It is driving as following Fig 12-1. (Ring Count M
ERRORNoERRORNoERRORNoNoNoNoYesSelect ON/OFF buttonSelect Mode buttonSelect FAN SPEED buttonSelect FAN DIR. buttonPower SupplyTEST STARTPower supply ag
62(0.5~24 HOUR)ERRORNoSelect TIMER ON ButtonSelect Timer Enter ButtonSelect CANCEL ButtonSelect ON/OFF ButtonSelect OFF (Timer) ButtonSelect SLEEP But
63(1) U1 (MICOM)123456789101112131415161718192021VDD(XTOUT)P22(XTIN)P21(INT5/STOP)P20P17P16(TC2)P15(PPG)P14(DVO)P13(INT2/TC1)P12(INT1)P11(INTO)P10(AIN
64(2) U2, 4 (KID65004) DARLINGTON ARRAYS(3) U8 (KIA7805P) : VOLTAGE REGULATOR (5VDC)(4) U7 (KIA7812P) : VOLTAGE REGULATOR (12VDC) IN1 1 16 OUT 1I
65(5) U9 (KIA7042P) : RESET ICKIA7042POUTLINEINPUTGROUNDOUTPUTVCC132OUTGND
661INDOOR UNITPROCEDURES PHOTOS 1. Stop the Air conditioner and disconnect the power cord from the wall outlet.2. Removing the Insert Grille and Frame
67◆DSA-185L, 185PPROCEDURES PHOTOS 1. Stop the Air conditioner and disconnect the power cord from the wall outlet.2. Removing the Insert Grille and Fr
68PROCEDURES PHOTOS 7. Removing the blower.After doing above procedures:! Loosen a screw for fixing holder bearing.@ Remove the blower.Fig 8Fig 7
6750Plate MountingREMOCONConnecting PipeGrille Insert179245REMOTE CONTROLLERFrame GrilleBodyPlate Mounting2. OUTLINE AND DIMENSIONS1INDOOR UNIT◆DSA-09
69PROCEDURES PHOTOS 1. Stop the operation of the Air conditioner and disconnect the power cordfrom the wall outlet.2. Removing the Insert Grille and F
2 OUTDOOR UNIT70◆DSA-095LPROCEDURES PHOTOS 1.Stop the operation of the air conditioner and disconnect the wire fromIndoor Unit to Outdoor Unit.2. Disa
71◆DSA-125L, 125P, DSA-185L, 185PPROCEDURES PHOTOS 1.Stop the operation of the air conditioner and dis connect the wire from indoor unit to out door u
◆DSA-245L, 245P72PROCEDURES PHOTOS 1.Stop the operation of the air conditioner and disconnect the wire from indoor unit to out door unit.2. Disassembl
733 EXPLODED VIEW & PARTS LIST (Indoor Unit)◆INDOOR UNIT EXPLODED VIEW: DSA-095L
74◆INDOOR UNIT PART LIST; DSA-095LNo PART CODE PART NAME Q'TY SPEC REMARK1 3100400301 BODY 1 HIPS T2.02 3108008700 MOTOR IDU 1 YDK-8-4A3 3101500
7526-1◆INDOOR UNIT EXPLODED VIEW: DSA-125L, 125P
76◆INDOOR UNIT PART LIST; DSA-125L, 125PNo PART CODE PART NAME Q'TY SPEC REMARK1 3110400301 BODY 1 HIPS T2.02 3118003500 MOTOR IDU 1 RB13B(220V,
77t0owapy16-175qj4szkheg16lcr89ixud23;f◆INDOOR UNIT EXPLODED VIEW: DSA-185L, 185P
78◆INDOOR UNIT PART LIST; DSA-185L, 185PNo PART CODE PART NAME Q'TY SPEC REMARK1 3100400101 BODY 1 HIPS2 3107600100 FLAP TOP 1 HIPS3 3107600200 F
7Insert Grille Frame GrilleBodyConnecting PipePlate Mounting815195285◆DSA-125L, 125PMODESLEEPON/OFFTIMERENTER/ CANCELFAN SPEEDTURBO/MILDFAN DIR.RE
7928-12827◆INDOOR UNIT EXPLODED VIEW: DSA-245L, 245P
80◆INDOOR UNIT PART LIST; DSA-245L, 245PNo PART CODE PART NAME Q'TY SPEC REMARK1 3100400600 BODY 12 3108007510 MOTOR IDU 1 IC-9430DWKF7A3 310150
814 EXPLODED VIEW & PARTS LIST (OUTDOOR UNIT)◆OUTDOOR UNIT EXPLODED VIEW: DSA-095L
8282◆OUTDOOR UNIT PART LIST; DSA-095LNo PART CODE PART NAME Q'TY SPEC REMARK1 3100014720 PAN BASE Ass`y 1 SECC T1.22 3106000900 COMP. BOLT 3 M8 x
83◆OUTDOOR UNIT EXPLODED VIEW: DSA-125L, 125P
84◆OUTDOOR UNIT PART LIST; DSA-125L, 125PNo PART CODE PART NAME Q'TY SPEC REMARK1 3110007500 PAN BASE Ass`y 12 3102100201 FOOT 4 SECC T2.03 31060
85◆OUTDOOR UNIT EXPLODED VIEW: DSA-185L, 185P
86◆OUTDOOR UNIT PART LIST; DSA-185L, 185PNo PART CODE PART NAME Q'TY SPEC REMARK1 3110007500 PAN BASE Ass`y 12 3102100201 FOOT 4 SECC T2.03 31060
87◆OUTDOOR UNIT EXPLODED VIEW: DSA-245L, 245P
88◆OUTDOOR UNIT PART LIST; DSA-245L, 245PNo PART CODE PART NAME Q'TY SPEC REMARK1 3100031102 BASE PAN Ass`y 1 SECC T1.22 3102100901 FOOT 2 SECC T
8◆ DSA-185L, 185P1035205322453¿‹ Æ˘˜ ˙`”fi `⁄˘˙`⁄„«…–‚fi‚ ˜‰˙‡»– ‚Ø– ‚–‰˙‡»– ‚ ˆ…Connecting PipeFilter-LFilter-RGrille InsertBodyPlateMounting4531035MOD
895 CONTROL BOX ASSEMBLY3874519q620◆DSA-095L
90◆DSA-095LNo PART CODE PART NAME Q'TY SPEC REMARK1 3114302010 CONTROL PCB ASS’Y12 3108914100 TERMINAL BLOCK 1 JXO-CH-3P3 3106900300 CAPACITOR SH
919◆DSA-125L, 125P
92◆DSA-125L, 125PNo PART CODE PART NAME Q'TY SPEC REMARK1 3110504000 CONTROL BOX 1 HIPS T2.0 (BLACK)2 3101301700 POWER CORD 1 250V 15A3 311430202
93◆DSA-185L, 185P
94No PART NAME SPEC Q’TY PART CODE REMARK1 CONTROL BOX ASS’Y 1 31000582102 BOX CONTROL-2 ABS (VERSION2) 1 31005069003 PCB TRANS ASS’Y DWA-220V 1 5EPV6
96◆DSA-245L, 245PNo PART CODE PART NAME Q'TY SPEC REMARK1 3100077060 CONTROL PCB ASS’Y12 3101200400 CLAMP POWER CORD 1 DA-5N3 3113701800 VOLTAGE
95◆DSA-245L, 245P
DEAWOO ELECTRONICS CO., LTD686, AHYEON-DONG MAPOGU,SEOUL, KOREA.C.P.O. BOX 8003 SEOUL KOREATELEX: DWELEC K28177-8CABLE:"DAEWOOELEC"FAX: +82-