Troubleshooting of Evaporator Sound
1. Hiss Sound from Capillary Tube
1) “I” tube is used to connect the
capillary tube and evaporator.
(2 welding points : , )
2. Shaking or trembling Sound of Evaporator
2) When such a sound is made,
attach a absorber on the tube
including 2 welding points.
1) Check whether evaporator is fastened tight
with the screws of 5 points.